TOP
TOP
[Dream Eye Center Equipment]
DREAM always prepares the most advanced
equipment and professional doctors for accurate
examination and surgery.
Special equipment Examination
ORB Scan
This optical mapping or corneal topography system mapping system is a diagnostic tool that shows the overall architecture of the cornea including surface power, thickness, front and back shape.
Cornea CT(Confoscan 4)
Examine cornea cell by cell
This is that analyze the pre and post surgerycondition of cornea. We were the first in Korea to introduce a cornea examination CT(CS4) for a more thorough presurgery examination system
TOPO
This allows us to analyze the curvature of corneal surface by showing colors depending on curvature. It is necessary for contact lens prescription or diagnosis for refractive surgery.
Fundus photography
This involves capturing a photograph of the back of the eye fundus The main structures that can be visualized on a fundus photo are the central and peripheral retina, optic disc and macula.
WAVE SCAN
The Wavefront laser can correct total aberrations. To optimize your vision and avoid night vision side effects (such as halos and night glare.)
OCT
Optical coherence tomography (OCT) is a non-invasive imaging test that uses light waves to take cross-section pictures of retina, the light-sensitive tissue lining the back of the eye. OCT is often used to evaluate disorders of the optic nerve. It is helpful in determining early state of glaucoma. Also can detect various of retina disease like retinal detachment and macular degeneration. OCT is most advice and latest technology.
AL scan
It measures 6 important indicators such as corneal curvature, ocular length, pupil size, corneal width, corneal thickness, and anterior depth in 10 seconds. Pupil size predicts the extent of light blur after correction of the visual acuity, and corneal thickness and anterior chamber depth are essential for glaucoma screening. In addition, corneal curvature and eyeball length are very important indicators to calculate intraocular lens power in cataract surgery.
Specular microscope
To check the corneal endothelial cells photographed to confirm if the number is within the normal range, and whether or not there is bullous keratopathy or Fuch's corneal dystrophy due to degeneration. It is also a very significant test in cases such as cataract and intraocular lens implantation where the incision of the cornea is required during
PENTACAM
This a rotating Scheimpflug camera system for anterior segment analysis. It measures topography and elevation of the anterior and posterior corneal surface and the corneal thickness
AMARIS RED +
Smart Pulse Technology
This collaboration has been worked for 10 years.
SCHWIND AMARIS 1050RS, the innovative laser system delivers an
unsurpassed repetition rate of 1050Hzcurrently the highest of all Excimer
lasers on the market and equips the world's only 7-dimensional eye
tracking device, was installed here in 2014 and continuous evolve.
(Certification for best skilled doctor)
The Wow Effect :
Back to work with good vision on Monday after operation on Friday!
The WOW Effect
SMART PULSE THCHNOLOGY
3-dimensional stereoscopic method
Based on Fullerene Structure, it recognizes corneal surface not as a plain disk but as a spherical surface in three-dimensions. So it can ablate corneal surface more smoothly and realistically.
What is WAVEFRONT?
is a technique of AMARIS RED that cuts the closest to the actual shape of cornea by 3-dimensional stereoscopic algorithm. Fast recovery in visual acuity with no high order aberration is realized due to smooth corneal surface ever after laser surgery.
What is Co-WAVE?
It analyzes all the refractive errors such as high-order aberration, tear film, vitreous body, retina, lens state and refractive information that occur in individuals, so it is possible to correct visual acuity accorded to any ocular abnormalities.
Advantage of WAVEFRONT
Corrected visual acuity is better than conventional refractive surgery
Excellent correction of astigmatism due to irregular astigmatism or corneal trauma
More accurate diagnosis by the measurement of the entire eye as well as corneal surface
Reduced risk of night vision disturbances such as glare or halos
Possible to re-operate the refractive error that is the side effect from conventional laser correction surgery
Even at night, the boundary of objects becomes more visible and high contrast sensitivity can be realized
Quick
menu
Total Eye Care
Laser Eye Correction, Presbyopia/Cataract,
Comprehensive Eye Examination
Dream is Different
Office Hours
*Please make reservation for your examination and consultation before your visit.
Please be noted that your reservation can only be confirmed after our reservation
team contact you over the phone or via email.
Direction
14th fl. Mijin Plaza, GangnamDaero 390
Gangnamgu, Seoul
South Korea. 06232
webmaster@hellolasik.com
Subway line 2 (Green line)/ Shinbundang line (Red line) Gangnam Station Exit 1.
*Taxi Please drop me off at Gangnam Station Exit 1 (Mijin Plaza).